HVAC Service DeskDuctCraft USA
(215) 975-8008
DuctCraft USA logo
DUCTCRAFT USA
Built to Fit. Engineered to Perform.
Duct design · Fabrication · Installation

DuctCraft USA,
built to fit.

We design, fabricate and install complete duct systems — for new construction, renovations, additions and homes where one room is always too hot or too cold. Sized by calculation, not by guesswork.

Your comfort is our peace of mind.

Sized by calculationLicensed & insured partnersEstimate from photosPermits in NJ & NY

Serving seven states from Baltimore to New York: MD, DE, PA, NJ, NY, VA & CT

Newly installed custom sheet-metal ductwork with offsets and transitions in a building under construction
Load calculation firstEvery system starts with the numbers
Made to measureTransitions, plenums and offsets fabricated for your space
Licensed install partnersInstalled by licensed, insured local companies
Permits handledWe open permits in New Jersey and New York

What we build

Duct work for every kind of job

Equipment is only half the system. The duct work decides whether the air actually gets where it belongs — quietly, evenly and without wasting energy.

Rectangular trunk ducts and round spiral ducts installed overhead in a new building

New construction & full replacements

Complete duct systems designed from the plans up: trunk lines, branches, returns and registers laid out for the equipment the building actually needs.

  • New homes and commercial build-outs
  • Rusted, crushed or undersized duct replacement
  • Return-air corrections — the most common comfort fix
Custom-fabricated galvanized duct sections, an elbow and a plenum box on a fabrication shop floor

Custom fabrication

When a standard fitting does not fit, we make the piece that does. Every transition and offset is fabricated to the measurements of your building — not forced in on site.

  • Transitions, plenums, elbows and offsets to order
  • Galvanized sheet metal, sealed and insulated where required
  • Additions, finished basements and attic conversions
Close-up of installed rectangular and round ductwork with sealed seams in a ceiling

Comfort problems, fixed at the duct

Hot and cold rooms, noisy vents and weak airflow are usually duct problems, not equipment problems. We find the restriction, resize the run and balance the system.

  • Airflow and static-pressure diagnosis
  • Added supplies and returns where rooms starve for air
  • Sealing and insulating existing duct runs

For renovators & builders

One package: design, equipment, install

Renovating or building? You do not need three contractors arguing with each other. We deliver the whole HVAC side of the project as one package, engineered before the first piece of metal is cut.

01Load calculationRoom-by-room heating and cooling load for the real building — insulation, windows, orientation.
02Duct designEvery run sized to velocity and static-pressure targets, drawn before fabrication starts.
03EquipmentNew Goodman, Daikin and Amana equipment matched to the calculation — never oversized by habit.
04InstallationLicensed, insured local partners install it; permits opened in New Jersey and New York.

From drawing to ceiling

Conflicts are cheap on paper. Every piece is counted, drawn and labelled before metal is cut — so installation goes up in order, not as a puzzle.

01

Take-off & coordination

Every fitting counted from your plans or photos and checked against structure and other trades before anything is cut.

02

Shop drawings

Gauge, seam, joint and sealing class fixed per piece — sized to velocity and static-pressure targets.

03

Cut, form & seal

Rectangular, round and spiral duct, plenums, transitions and curb adapters — sealed at the bench and labelled to the drawing.

04

Delivered in install order

Metal arrives bundled in the order it goes up, with the hardware to start hanging the same morning.

Galvanized steel

The default for supply, return and general exhaust — coated stock, sealed and labelled by drawing.

Stainless & aluminum

Stainless for kitchen and lab exhaust; aluminum where rooftop weight matters.

Insulated & double-wall

Insulated runs where condensation, noise or energy loss is the enemy.

How we size it

Designed to the numbers

Air has rules. These are the targets every duct system we design is checked against — the difference between a quiet, even system and one that whistles, rattles and leaves rooms behind.

Main trunk ducts600–1,200 FPMThe highways of the system — fast enough to stay compact, slow enough to stay quiet.
Branch ducts400–800 FPMRuns feeding individual rooms, sized per room load.
Registers & grilles200–400 FPMSlow at the outlet, so air enters the room without noise or drafts.
The noise line> 1,500 FPMPast this speed you get whistling, pressure loss and a blower working against itself.

Rectangular ducts: keep the shape honest

A flat, wide duct wastes metal and pressure. We keep the aspect ratio under 4:1 — ideally between 1:1 and 2:1 — so the duct carries its rated airflow without stealing static pressure.

Static pressure: every part counts

Total static pressure is the sum of everything the air has to push through. We add it up before we build — not after the blower starts struggling.

Duct runs+ Fittings+ Filter+ Coil+ Registers= Total static pressure

Duct size calculator

What size duct do you need?

Pick your system size and the type of run. The calculator uses the same velocity targets we design to, and shows the round duct — or rectangular options — that carry your airflow.

Rule of thumb used: about 400 CFM per ton of cooling. Final sizing for a real project comes from the load calculation and the full static-pressure budget.

14″Round duct diameter
154 in²Free area needed
900Design velocity, FPM
04008001,2001,600 FPM

    How it works

    From photos to finished duct work

    No sales visit needed. We estimate remotely from your photos and measurements, design on paper, and only then send the crew.

    1Call or text us

    Send photos or a short video of the space and the existing system, plus rough measurements. That is enough to start.

    2We calculate & design

    Load calculation and a duct layout sized to the velocity and static-pressure targets above — before anything is fabricated.

    3Your exact quote

    You get the exact price for your project in writing — equipment and installation quoted as separate lines, no surprises inside the total.

    4Fabrication & install

    Custom pieces are fabricated to the design, and licensed, insured local partners install them. Permits handled in NJ and NY.

    Questions

    Before you call

    One room is always too hot or too cold. Is it the duct work?

    Usually, yes. An undersized branch, a missing return or a crushed run starves that room of air while the equipment itself is fine. Resizing the run and adding a return fixes most cases without replacing the system.

    Do you have to visit my home before quoting?

    No. Our estimates are done remotely: you send photos or video of the space and the current system, we guide you on what to measure, and the design and exact quote are built from that. The only visit is the installation itself.

    I am renovating. Can you do the whole HVAC side?

    Yes — that is exactly the package above: load calculation, duct design, new equipment and installation by licensed partners, as one coordinated job. Send us the plans or photos of the project and we will scope it.

    Why are my vents so loud?

    Noise means the air is moving too fast for the duct it is in — often past 1,500 FPM through an undersized run or register. The fix is more duct area, not a quieter thermostat: larger runs, gentler fittings and outlets sized for 200–400 FPM.

    Talk to us about your duct work

    Send photos of your space or your plans — we will tell you honestly whether you need new duct work, a correction, or nothing at all.

    (215) 975-8008

    Call or text anytime · Text line: (888) 779-8008

    Photo Assistant — size your duct from a photo

    Upload a photo or short video of your duct or room. Tell the assistant one known size in the photo (for example, your tape measure), and it estimates the duct size and airflow. Final size is confirmed after we review your photos.







    Call (215) 975-8008 · Send your photo in Messenger for a confirmed size.

    Need HVAC equipment? HVAC Service Desk — Goodman systems, delivery & installation.

    Privacy Policy · Complaints · Call (215) 975-8008

    Static pressure budget

    Add the losses. Total static pressure = duct + fittings + filter + coil + diffuser losses.

    Request estimate